Gasification boiler for wood
- Technical details
-
Wood boilers ATMOS Generator DC15GS, DC20GS, DC25GS, DC32GS and DC40GS with a large application space lined with ceramics for optimal combustion quality. It’s a real wood gas generator.
Advantages of gasification boilers for piece wood ATMOS
- Option to burn large pieces of wood
- Large space for wood – long burning time – up to 12 hours, depending on boiler type
- High efficiency 88,8 to 91,2 % depending on the type – primary and secondary air is preheated to a high temperature
- Ceramic loading chamber – fuel pre-drying
- Ceramic combustion chamber
- Ecological combustion – boiler according to EN 303-5:2012 class 5, EKODESIGN 2015/1189
- Exhaust fan – dust-free ash removal, smokeless boiler room
- Cooling loop against overheating – without the risk of damaging the boiler
- Automatic shutdown of the boiler after the fuel burns out – flue gas thermostat
- Convenient ash removal – large space for ash (when burning wood, clean it 1x / week)
- Boiler without tubesheet – easier cleaning
- Small size and low weight
- Possibility of choosing a door R / L (right/left) for selected types
- Possibility of connection without accumulation tank
- High Quality
- DC15GS, DC20GS, DC25GS, DC32GS, DC40GS ATMOS Generátor
- DC50GSX
- DC70GSX
- Combustion chamber with heat-resistant fitting – nozzle
- Velikost přikládacího otvoru
- View of bottom combustion chamber
- Flame in the lower combustion chamber
- Exhaust fan and flue gas neck
- Upper cleaning lid at the rear of the boiler
Installation
ATMOS boilers must be connected via the LADDOMAT 22 or ESBE thermoregulation valve (three-way valve controlled by actuator in case of using electronic regulation ATMOS ACD 03/04) to achieve keeping the minimum temperature of water returning to boiler at 65 °C. The temperature of water exiting the boiler must be permanently kept between 80 – 90 °C. The default configuration of all boilers includes a cooling circuit to prevent overheating. We recommend installing boilers with accumulation tanks.
- Laddomat 22
- Cooling loop against overheating and draught regulator FR124
- Boiler wiring diagram with Laddomat 22 without storage tanks
- Boiler wiring diagram with ACD 03 control and storage tanks
Boilers regulation
Electromechanical regulation – boiler performance is regulated by an air regulating valve controlled by a draft regulator, FR 124 type, which automatically opens or closes the air valve according to the set water outlet temperature (80 – 90 °C). In addition to performance regulation, the draft regulator helps protect the boiler against overheating. Its advantage is a quick ignition and firing up to the required output when the air valve is fully open. The boilers are equipped with a control thermostat on the instrument panel, which controls the exhaust fan according to the set water outlet temperature (80 – 85 °C) and a flue gas thermostat, which is used to shut down the boiler and turn off the exhaust fan after the fuel has burned out. In the case of connecting a boiler with accumulation tanks, the flue gas thermostat also controls the operation of the pump in the boiler circuit.
The advantage of regulation and design of ATMOS boilers is that the boilers work with a good chimney draft up to 70 % of the nominal power even without a fan.
- Boiler control panel with standard regulation
Panel composition:
Main off switch, safety thermostat, thermometer, regulator thermostat and combustion thermostat
Electro-mechanical regulation is an optimal solution for easy management of the operation of the boiler (ventilator). The design of the panel with standard regulation is a basic design for all produced boilers.
Equithermal regulation ACD 03
Each boiler can be equipped with a modern touch electronic control ATMOS ACD 03 for controlling the entire heating system depending on the outdoor temperature, room temperature and time. This regulation is able to control the boiler itself with a fan with many other functions.
- Boiler control panel with equithermal regulation ATMOS ACD 03
Equithermal regulation ACD 04
The boilers DC25GS, DC32GS can be ordered from the factory with built-in ATMOS ACD 04 touch screen control.The boilers are allready equipped with all necessary sensors.This unit is designed for comfortable control of the hot water system of the heated building. The controller contains functions for direct control of the boiler, boiler circuit, three heating circuits, domestic hot water, solar, etc.
- Boiler control panel with equithermal regulation ATMOS ACD 04
Technical details
Description of the boiler drawing | |||
1. | Boiler body | 22. | Draught regulator – HONEYWELL FR124 |
2. | Filling door – upper | 23. | Cooling loop protecting against overheating |
3. | Ashtray door – lower | 24. | Fan control thermostat (boiler) |
4. | Exhaust fan (S) | 25. | Door panel – Sibral |
5. | Heat-resistant fitting – nozzle | 26. | Door seal – cord 18 x 18 |
6. | Control panel | 29. | Capacitor for exhaust fan – 1μF |
7. | Safety thermostat | 33. | Flue gas brake (DC32GS, DC40GS) |
8. | Control flap | 35. | Waste gas thermostat |
9. | Heat-resistant fitting – side of the combustion chamber | 36. | Safety thermostat (Caution – when overheating push on) |
10. | Heat-resistant fitting – spherical space L + R | 39. | Air braker along spherical space |
11. | Nozzle seal | 42. | Primary air regulation |
12. | Heat-resistant fitting – half-moon | 43. | Secondary air regulation |
13. | Firing up valve | ||
14. | Heat-resistant fitting – rear part of spherical space | ||
15. | Cleaning lid | K | – the flue-gas duct neck |
17. | Fire valve stem | L | – the boiler water outlet |
18. | Thermometer | M | – the boiler water inlet |
19. | Frame screen | N | – filling valve pipe sleeve |
20. | Switch with an indicator light | P | – sleeve for a sensor of the valve which regulates the cooling loop |
Boiler dimensions (mm) |
|||||||
---|---|---|---|---|---|---|---|
DC15GS | DC20GS | DC25GS | DC32GS | DC40GS | DC50GSX | DC70GSX | |
A | 1280 | 1280 | 1280 | 1280 | 1434 | 1563 | 1686 |
B | 670 | 758 | 959 | 959 | 959 | 1042 | 1268 |
C | 678 | 678 | 678 | 678 | 678 | 678 | 678 |
D | 950 | 950 | 950 | 950 | 1099 | 997 | 1086 |
E | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 180 |
F | 69 | 69 | 69 | 69 | 69 | 70 | 58 |
G | 185 | 185 | 185 | 185 | 185 | 184 | 184 |
H | 1008 | 1008 | 1008 | 1008 | 1152 | 1287 | 1407 |
CH | 256 | 256 | 256 | 256 | 256 | 256 | 256 |
I | 256 | 256 | 256 | 256 | 256 | 256 | 256 |
J | 6/4″ | 6/4″ | 6/4″ | 6/4″ | 2″ | 2″ | 2″ |
Specification |
Boiler type | |||||||
DC15GS | DC20GS | DC25GS | DC32GS | DC40GS | DC50GSX | DC70GSX | ||
Boiler heat output | kW |
15 | 20 | 25 | 32 | 40 | 49 | 70 |
Boiler thermal input | kW | 16,4 | 21,9 | 27,4 | 35,1 | 45,0 | 53,8 | 77,5 |
Heating surface | m2 | 1,8 | 2 | 2,7 | 2,9 | 3,2 | 3,5 | 4,3 |
Fuel shaft volume | dm3 (l) |
66 | 80 | 120 | 120 | 160 | 210 | 280 |
Filling hole dimensions | mm | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 310 | 450 x 310 |
Prescripted chimney draft | Pa/mbar |
16/0,16 | 20/0,20 | 23/0,23 | 25/0,25 | 25/0,25 | 25/0,25 | 26/0,26 |
Max. working water overpressure | kPa/bar | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 |
Boiler weight | kg |
302 | 343 | 431 | 436 | 485 | 538 | 690 |
Gas-outlet pipe diameter | mm | 150/152 | 150/152 | 150/152 | 150/152 | 150/152 | 150/152 | 180 |
Ingress protection of electric parts | IP | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Electrical power input (auxiliary) | W | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Electrical input in standby mode | W | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Ignition mode | manual | |||||||
Efficiency over the entire performance range | % |
91,2 | 90,6 | 90,3 | 89,3 | 88,8 | 90,6 | 90,3 |
Boiler class | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Boiler category | 1 | |||||||
Operating mode | non-condensing | |||||||
Energy efficiency class | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |
Waste gas temperature at nominal output | °C | 134 | 166 | 158 | 171 | 250 | 165 | 161 |
Waste gas combustion products flow weight at nominal output | kg/s | 0,010 | 0,012 | 0,015 | 0,018 | 0,022 | 0,025 | 0,034 |
Specified fuel (preffered) | Dry wood with a calorific value of 15 – 17 MJ/kg-1, water content 12 – 20 %, diameter 80 – 120 mm | |||||||
Average fuel consumption for the heating season | kg.h-1 | 4,1 | 5,5 | 6,8 | 8,6 | 10 | 13 | 18 |
Prescribed wood length | mm |
250 | 330 | 530 | 530 | 530 | 530 | 730 |
Combustion time at nominal output | Hours | 2 | 2 | 3 | 2 | 3 | 3 | 3 |
The volume of water in the boiler | l |
56 | 64 | 80 | 80 | 90 | 120 | 170 |
Boiler hydraulic loss | mbar | 0,20 | 0,22 | 0,22 | 0,23 | 0,22 | 0,23 | 0,22 |
Minimum buffer tank volume | l | 500 | 500 | 500 | 500 | 500 | 500 | 750 |
Connecting voltage | V/Hz | 230/50 | ||||||
Minimum return water temperature during operation | 65 °C | |||||||
EKODESIGN | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |