Wood boilers ATMOS Generator DC15GS, DC20GS, DC25GS, DC32GS and DC40GS with a large application space lined with ceramics for optimal combustion quality. It’s a real wood gas generator.
Advantages of gasification boilers for piece wood ATMOS
- Possibility to burn large pieces of wood
- Large fuel tank – long burning time
- High efficiency 85 to 90 % depending on the type – primary and secondary air is preheated to a high temperature
- Ecological combustion – boiler according to EN 303-5:2012 class 5, EKODESIGN 2015/1189
- Exhaust fan – dust-free ash removal, smoke-free boiler room
- Cooling loop against overheating – without the risk of damaging the boiler
- Automatic shutdown of the boiler after the fuel burns out – flue gas thermostat
- Convenient ash removal – large ceramic combustion chamber for ash (cleaning once a week)
- Boiler without tubesheet – easier cleaning
- Small size and low weight
- Choice of door left / right
- High Quality
- DC15GS, DC20GS, DC25GS, DC32GS, DC40GS ATMOS Generátor
- DC50GSX
- DC70GSX
- Velikost přikládacího otvoru
- Combustion chamber with heat-resistant fitting – nozzle
- Flame in the lower combustion chamber
- View of bottom combustion chamber
- Exhaust fan and flue gas neck
- Upper cleaning lid at the rear of the boiler
Installation
ATMOS boilers must be connected via the LADDOMAT 22 or ESBE thermoregulation valve (three-way valve controlled by actuator in case of using electronic regulation ATMOS ACD 03/04) to achieve keeping the minimum temperature of water returning to boiler at 65 °C. The temperature of water exiting the boiler must be permanently kept between 80 – 90 °C. The default configuration of all boilers includes a cooling circuit to prevent overheating. We recommend installing boilers with accumulation tanks.
- Laddomat 22
- Cooling loop against overheating and draught regulator FR124
- Boiler wiring diagram with Laddomat 22 without storage tanks
- Boiler wiring diagram with ACD 03 control and storage tanks
Boilers regulation
Electromechanical – Power is controlled with a safety valve operated with the draught regulator, FR 124 type, which automatically opens or closes the safety valve according to a set output temperature of water (80 – 90°C). When setting the power regulator, much attention should be paid because the regulator has another important function other than power regulation – it also secures the boiler against overheating. A controlling thermostat located on the boiler panel regulates the fan according to a set temperature (75 – 85 °C). A temperature lower by 5 °C should be set on the controlling thermostat rather than on the FR 124 draught regulator.
The boiler runs at a reduced output even without a fan – heating is not lost when the electric power fails. At up to 70 percent of its rated output, the boiler can be operated without a ventilator.

Boiler control panel with standard regulation
Panel composition:
Main off switch, safety thermostat, thermometer, regulator thermostat and combustion thermostat
Electro-mechanical regulation is an optimal solution for easy management of the operation of the boiler (ventilator). The design of the panel with standard regulation is a basic design for all produced boilers.
Equithermal regulation ACD 03
Each boiler can be equipped with a modern touch electronic control ATMOS ACD 03 for controlling the entire heating system depending on the outdoor temperature, room temperature and time. This regulation is able to control the boiler itself with a fan with many other functions.

Boiler control panel with equithermal regulation ATMOS ACD 03
Equithermal regulation ACD 04
The boilers DC25GS, DC32GS can be ordered from the factory with built-in ATMOS ACD 04 touch screen control.The boilers are allready equipped with all necessary sensors.This unit is designed for comfortable control of the hot water system of the heated building. The controller contains functions for direct control of the boiler, boiler circuit, three heating circuits, domestic hot water, solar, etc.

Boiler control panel with equithermal regulation ATMOS ACD 04
Technical details
Description of the boiler drawing | |||
1. | Boiler body | 22. | Draught regulator – HONEYWELL FR124 |
2. | Filling door – upper | 23. | Cooling loop protecting against overheating |
3. | Ashtray door – lower | 24. | Fan control thermostat (boiler) |
4. | Exhaust fan (S) | 25. | Door panel – Sibral |
5. | Heat-resistant fitting – nozzle | 26. | Door seal – cord 18 x 18 |
6. | Control panel | 29. | Capacitor for exhaust fan – 1μF |
7. | Safety thermostat | 33. | Flue gas brake (DC32GS, DC40GS) |
8. | Control flap | 35. | Waste gas thermostat |
9. | Heat-resistant fitting – side of the combustion chamber | 36. | Safety thermostat (Caution – when overheating push on) |
10. | Heat-resistant fitting – spherical space L + R | 39. | Air braker along spherical space |
11. | Nozzle seal | 42. | Primary air regulation |
12. | Heat-resistant fitting – half-moon | 43. | Secondary air regulation |
13. | Firing up valve | ||
14. | Heat-resistant fitting – rear part of spherical space | ||
15. | Cleaning lid | K | – the flue-gas duct neck |
17. | Fire valve stem | L | – the boiler water outlet |
18. | Thermometer | M | – the boiler water inlet |
19. | Frame screen | N | – filling valve pipe sleeve |
20. | Switch with an indicator light | P | – sleeve for a sensor of the valve which regulates the cooling loop |
Boiler dimensions (mm) |
|||||||
---|---|---|---|---|---|---|---|
DC15GS | DC20GS | DC25GS | DC32GS | DC40GS | DC50GSX | DC70GSX | |
A | 1280 | 1280 | 1280 | 1280 | 1434 | 1563 | 1686 |
B | 670 | 758 | 959 | 959 | 959 | 1042 | 1268 |
C | 678 | 678 | 678 | 678 | 678 | 678 | 678 |
D | 950 | 950 | 950 | 950 | 1099 | 997 | 1086 |
E | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 180 |
F | 69 | 69 | 69 | 69 | 69 | 70 | 58 |
G | 185 | 185 | 185 | 185 | 185 | 184 | 184 |
H | 1008 | 1008 | 1008 | 1008 | 1152 | 1287 | 1407 |
CH | 256 | 256 | 256 | 256 | 256 | 256 | 256 |
I | 256 | 256 | 256 | 256 | 256 | 256 | 256 |
J | 6/4″ | 6/4″ | 6/4″ | 6/4″ | 2″ | 2″ | 2″ |
Specification |
Boiler type | |||||||
DC15GS | DC20GS | DC25GS | DC32GS | DC40GS | DC50GSX | DC70GSX | ||
Boiler heat output | kW |
15 | 20 | 25 | 32 | 40 | 49 | 70 |
Boiler thermal input | kW | 16,4 | 21,9 | 27,4 | 35,1 | 45,0 | 53,8 | 77,5 |
Heating surface | m2 | 1,8 | 2 | 2,7 | 2,9 | 3,2 | 3,5 | 4,3 |
Fuel shaft volume | dm3 (l) |
66 | 80 | 120 | 120 | 160 | 210 | 280 |
Filling hole dimensions | mm | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 260 | 450 x 310 | 450 x 310 |
Prescripted chimney draft | Pa/mbar |
16/0,16 | 20/0,20 | 23/0,23 | 25/0,25 | 25/0,25 | 25/0,25 | 26/0,26 |
Max. working water overpressure | kPa/bar | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 | 250/2,5 |
Boiler weight | kg |
302 | 343 | 431 | 436 | 485 | 538 | 690 |
Gas-outlet pipe diameter | mm | 150/152 | 150/152 | 150/152 | 150/152 | 150/152 | 150/152 | 180 |
Ingress protection of electric parts | IP | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Electrical power input (auxiliary) | W | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Electrical input in standby mode | W | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Ignition mode | manual | |||||||
Efficiency over the entire performance range | % |
91,2 | 90,6 | 90,3 | 89,3 | 88,8 | 90,6 | 90,3 |
Boiler class | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Boiler category | 1 | |||||||
Operating mode | non-condensing | |||||||
Energy efficiency class | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |
Waste gas temperature at nominal output | °C | 134 | 166 | 158 | 171 | 250 | 165 | 161 |
Waste gas combustion products flow weight at nominal output | kg/s | 0,010 | 0,012 | 0,015 | 0,018 | 0,022 | 0,025 | 0,034 |
Specified fuel (preffered) | Dry wood with a calorific value of 15 – 17 MJ/kg-1, water content 12 – 20 %, diameter 80 – 120 mm | |||||||
Average fuel consumption for the heating season | kg.h-1 | 4,1 | 5,5 | 6,8 | 8,6 | 10 | 13 | 18 |
Wood lenght | mm |
250 | 330 | 530 | 530 | 530 | 530 | 730 |
Combustion time at nominal output | Hours | 2 | 2 | 3 | 2 | 3 | 3 | 3 |
The volume of water in the boiler | l |
56 | 64 | 80 | 80 | 90 | 120 | 170 |
Boiler hydraulic loss | mbar | 0,20 | 0,22 | 0,22 | 0,23 | 0,22 | 0,23 | 0,22 |
Minimum buffer tank volume | l | 500 | 500 | 500 | 500 | 500 | 500 | 750 |
Connecting voltage | V/Hz | 230/50 | ||||||
Minimum return water temperature during operation | 65 °C | |||||||
EKODESIGN | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |