7. Stand-by electrical power supply UPS

Code: P0072

Záložní zdroj

Code  
P0072 UPS 300/3 hod.

A stand-by electrical power supply which is built into the electrical switch board to which all regulated elements of the heating system are connected. It is equipped with a maintenance free battery which is able to maintain the functioning of one pump and boiler for approx. 3 hrs.

1. Technical data

1. Input range ssU 10 - 15 V
2. Alternating input U 230 V / 50 Hz
3. Maximum power output 300 W
4. Efficiency 90%
5. Battery discharge check ANO při 10 - 11 V
6. Overload protection ANO
7. Short-circuit protection ANO
8. Maximum charging current 0,6 A
9. Coverage 1 P - 20
10. Dimensions 390 x 310 x 130

2. Application

This stand-by electrical power supply provides emergency electrical power to the heating system pump and electronic regulation during an electrical power failure so as to prevent overheating of the boiler. It is advantageous particularly in such situations where the connection with the cooling loop cannot be efficiently utilized or where the cooling loop is not installed by the manufacturer (fireplaces, older boiler types). It is unsuitable to install this equipment on a boiler which is supplied by its own water supply (e.g. water well). In such case the cooling loop is insignificant since during an electrical power outage, there will be no water flow.

3. Device description

The power supply works automatically and is able to supply electrical power to the connected pump and electronic regulation for approximately 3 hours during an electrical power outage. The maximal output load is 300 W. (see manufacturers notice)

This device is equipped with protective components against overloading, overheating, short-circuiting, battery discharge and low voltage. Should the voltage fall below 10.7 V, an acoustic signal will sound from the device. Below 10.0 V the device will automatically disconnect and stop supplying the connected equipment. The 3-hour time limit is sufficient to burn out the last of the fuel.

Under no circumstance can this stand-by electrical power supply act as a power source for a continuing heating process with the addition of new fuel to the boiler but can only act as protection against overheating, where there is no cooling loop installed or where one cannot be installed.

The stand-by electrical power supply is equipped with a 230 V power outlet for connection of the boiler; however this outlet is not protected against power outage. The installed 12 V - 18 Ah battery is maintenance free and is automatically charged.


The Latest News

Pricelist

Equithermal regulation

Accessories for boilers

Other 42 recommended configuration of installation

Boiler-room for pellet boiler

Exhibitions where you can find us

16 - 19. 1. Infotherma - Ostrava

7.-10.2. Aqua-therm – Nitra

7.-10.2. Interclima + Elec - Paříž

Useful Links

 

ISO

ISO 14001
ISO 14001
ISO 9001
ISO 9001
ISO 18001
ISO 18001