Briquette and wood gasification boilers

- BOILER DC 14 R
The ecological hot water boilers ATMOS DC14R, DC24RS, DC30RS are destined for heating the one-family houses, weekend houses, cottages and similar houses with 15-32 kW heat losses. The boilers are constructed only for combustion of good quality wood briquettes and lump wood. Any dry wood can be used for heating, especially the wooden logs, cleft timber up to 330 mm length and good quality wood briquettes with 75-100 mm diameter and 200 - 300 mm length. It is also possible to use the wood with a higher diameter in the form of blocks which decreases the rated output and prolongs the combustion time. The boiler is not destined for combustion of lignite and hard coal, sawdust and petite wood waste. The coal briquettes can be used as an alternative fuel in case of emergency. The boilers with their ample hoppers make it possible to use the whole packets of briquettes and big wood blocks.
BOILER DC 14 R
- boiler without suction fan
- specified fuel – LOG WOOD
lenght 250 – 330 mm - alternative fuel – WOOD BRIQUETTES
diameter 75 – 100 mm, lenght 200 – 300 mm
BOILER DC 24 RS, BOILER DC 30 RS
- boiler with suction fan
- specified fuel – WOOD BRIQUETTES
diameter 75 – 100 mm, lenght 200 – 300 mm - rear flue way with turbulator
- alternative fuel – LOG WOOD
lenght 250 – 330 mm
ADVANTAGES OF ATMOS BOILERS
- special boilers for gasifying - Wood briquettes - Wood
- Ceramic gasifying chamber with rotating cast iron grate with intake of secondary preheated air – good combustion by firing up and fast achieving of operation temperature
- construction of the boiler shows new way of briquettes and wood gasification – the grate is set into ceramic shaped parts.
- easy cleaning of boiler even by operating – simply cleaning of burning chamber rear flue way and turbulator from ash
- high efficiency around 90%
- modern design and attractive price

- Boiler DC24RS, DC30RS

- Wood briquettes

- Briquette gasification boilers

- design of upper chamber

| DIMENSIONS | DC 14 R | DC 24 RS | DC 30 RS |
|---|---|---|---|
| A | 1198 | 1279 | 1279 |
| B | 694 | 762 | 842 |
| C | 672 | 678 | 678 |
| D | 690 | 949 | 722 |
| E | 152 | 152 | 152 |
| F | 65 | 69 | 69 |
| G | 208 | 184 | 184 |
| H | 933 | 1005 | 1005 |
| CH | 212 | 256 | 256 |
| I | 212 | 256 | 256 |
| J | 6/4” | 6/4” | 6/4” |
| TYPE ATMOS | DC 14 R | DC 24 RS | DC 30 RS | |
|---|---|---|---|---|
| POWER OUTPUT RANGE | kW | 14,9 | 26 | 32 |
| SPECIFIED STACK DRAUGHT | Pa | 18 | 22 | 24 |
| BOILER WEIGHT | kg | 294 | 331 | 365 |
| VOLUME OF HOPPER | dm3 | 65 | 93 | 93 |
| SPECIFIED FUEL | BILLET WOOD | BRIQUETTES | BRIQUETTES | |
| SUBSTITUTE FUEL | BRIQUETTES | BILLET WOOD | BILLET WOOD | |
| MAXIMUM WOOD LENGHT | mm | 330 | 330 | 330 |
| VOLUME OF WATER | l | 45 | 58 | 65 |
| MINIMUM TEMPERATURE OF RETURN WATER | 65 °C | |||
| EFFICIENCY IN THE WHOLE RANGE OF POWER OUTPUT | % | 82 | 86 | > 90 |
| CO * | mg/m3 | <3200 | <500 / <500 | <200 / <1000 |
| DUST * | mg/m3 | 35 | 15 / 6 | 14 / 15 |
| CLASS OF BOILER EN 303-5 | 3 | 3 | 3 | |
* Quality of burning recounted to 10 % of O2 in waste gas